For the parallel pipe system shown below, the lengths and sizesare provided below.  The water surface elevation ofreservoir A is 106 feet and reservoir B is 88feet.  Assume the friction factor for all pipes is0.0182.  What is the approximate flow percentagedistribution?

For the system in the previous question,what is the flow ratebetween Reservoir A and Reservoir B, in cubic feet per second?

QUESTION 5 For the parallel pipe system shown below, the lengths and sizes are provided below. The water surface elevation of

QUESTION 5 For the parallel pipe system shown below, the lengths and sizes are provided below. The water surface elevation of reservoir A is 106 feet and reservoir B is 88 feet. Assume the friction factor for all pipes is 0.0182. What is the approximate flow percentage distribution? Pipe Length AB BC, (top) BC, (bottom) CD B D (in) 24 14 16 24 500 4,000 2,362 500 N.T.S. a. BC1 = 18.5 %; BC2 = 81.5% b. BC1 = 75.5 %; BC2 = 24.5% c. BC1 = 24.5 %; BC2 = 75.5% d. BC1 = 35.5 %; BC2 = 64.5% QUESTION 6 For the system in the previous question, what is the flow rate between Reservoir A and Reservoir B, in cubic feet per second?


We have an Answer from Expert

View Expert Answer

Expert Answer


Answer to For the parallel pipe system shown below, the lengths and sizes are provided below. The water surface elevation of reser...

The Problem has Answer!

We have detailed solutions for you for more understanding.

View Answer